PHV RANGE

PHV RANGE

Technical data  | Technical data recessed
  • Mounting height surface mounted 4m
  • Mounting Height recessed 3.75m
  • 3-way valve (water units)
  • Available in Electric, Water and Ambient
  • Tangential fans
  • Optional remote thermostat
  • Optional schedule automation
  • Optional door contact switch

Scope of Application

The PHV range of units are suitable for installations where a more powerful air barrier is desired due to a higher volume of traffic such as: department stores, cinemas, high street shops, or even grocery store vestibules when employee and customer comfort is paramount due to extreme climate conditions. PHV units are high velocity and high output units that make them suitable for industrial applications such as food processing plants, factories and warehouses. PHV units are ideally suited for shipping and receiving doors where an air barrier is necessary in saving energy costs.

Features

The surface mounted PHV range NT air curtain has a streamlined steel casing with plastic end caps. The recessed model is supplied with an anodized aluminum grille. The aerodynamic design and tangential fans produce an optimal and uniform airflow creating a wall of air that allows unobstructed traffic through the air door.

Controls

All PHV range NT air curtains are supplied standard with a wall mounted slide switch controller. A remote thermostat, or automation protocol, or door contact switch can be incorporated.

PHV RANGE NT

Mounting Height Max. 4.0m 

Models
Metric
Imperial
Dimensions
(mm)
(in)
Supply
(60Hz)
#
Motors
@HP
Heat
Output
(kW)
(Btu/hr)
Loading
(A) *per
phase
Max.
Velocity
(m/s)
(ft/min)
Max. Air
Volume
(m³/h)
(ft³/min)
Weight
(kg)
(Ibs)
dB(A)
@3m
                   
Ambient 120V
PHV1000A NT
1196(l) x 377(d) x 255(h)
47(l) x 15(d) x 10(h)
120V~1P&N
1@1/4
-
3.2
11.5
2,260
2,880
1,700
30
66
59
PHV1500A NT
1746(l) x 377(d) x 255(h)
69(l) x 15(d) x 10(h)
120V~1P&N
1@1/3
-
5.0
11.5
2,260
4,020
2,370
47
104
60
PHV2000A NT
2296(l) x 377(d) x 255(h)
90(l) x 15(d) x 10(h)
120V~1P&N
2@1/4
-
6.5
11.5
2,260
5,760
3,390
62
137
61
Electric 208V
PHV1000E NT
1196(l) x 377(d) x 255(h)
47(l) x 15(d) x 10(h)
208V~3P&N
1@1/4
6/12
20,490/40,980
37
11.5
2,260
2,880
1,700
31
68
59
PHV1500E NT
1746(l) x 377(d) x 255(h)
69(l) x 15(d) x 10(h)
208V~3P&N
1@1/3
9/18
30,735/61,470
55
11.5
2,260
4,020
2,370
48
106
60
PHV2000E NT
2296(l) x 377(d) x 255(h)
90(l) x 15(d) x 10(h)
208V~3P&N
2@1/4
12/24
40,980/81,970
73
11.5
2,206
5,760
3,390
64
140
61
LPHW 120V
PHV1000W NT
1196(l) x 377(d) x 255(h)
47(l) x 15(d) x 10(h)
120V~1P&N
1@1/4
12
40,490
3.2
11.0
2,170
2,630
1,550
32
70
59
PHV1500W NT
1746(l) x 377(d) x 255(h)
69(l) x 15(d) x 10(h)
120V~1P&N
1@1/3
18
61,470
5.0
11.0
2,170
3,670
2,160
50
110
60
PHV2000W NT
2296(l) x 377(d) x 255(h)
90(l) x 15(d) x 10(h)
120V~1P&N
2@1/4
24
81,970
6.5
11.0
2,170
5,260
3,095
66
145
61
Electric 600V
PHV1000E NT
1196(l) x 377(d) x 255(h)
47(l) x 15(d) x 10(h)
600V~3P&N
1@1/4
6/12
20,490/40,980
12.7
11.5
2,260
2,880
1,770
29
64
59
PHV1500E NT
1746(l) x 377(d) x 255(h)
69(l) x 15(d) x 10(h)
600V~3P&N
1@1/3
9/18
30,735/61,470
19.5
11.5
2,260
4,020
2,370
45
100
60
PHV2000E NT
2296(l) x 377(d) x 255(h)
90(l) x 15(d) x 10(h)
600V~3P&N
2@1/4
12/24
40,980/81,970
25.4
11.5
2,260
5,760
3,390
61
135
61

Electric units require a “4 wire + ground” electric supply cable to allow for the hook up of N (neutral).
Noise levels are given as a guide only. Variations from this can arise depending on the size of the room the unit is installed in, its acoustic characteristics and the position of the listener.
 

PHV RANGE RECESSED

Mounting Height Max. 3.75m 

Models
Metric
Imperial
Dimensions
(mm)
(in)
Grille Size
inc. Flange
(mm)
Supply
(60Hz)
#
Motors
@HP
Heat
Output
(kW)
(Btu/hr)
Loading
(A) *per
phase
Max.
Velocity
(m/s)
(ft/min)
Max. Air
Volume
(m³/h)
(ft³/min)
Weight
(kg)
(Ibs)
dB(A)
@3m
                     
Ambient 120V
PHV1000AR
1150(l) x 436(d) x 296(h)
45(l) x 17(d) x 12(h)
1104 x 436
120V~1P&N
1@1/4
-
3.2
11.0
2,170
2,750
1,620
38
84
59
PHV1500AR
1650(l) x 436(d) x 296(h)
65(l) x 17(d) x 12(h)
1604 x 436
120V~1P&N
1@1/3
-
5.0
11.0
2,170
3,840
2,260
51
112
60
PHV2000AR
2240(l) x 436(d) x 296(h)
88(l) x 17(d) x 12(h)
2190 x 436
120V~1P&N
2@1/4
-
6.5
11.0
2,170
5,500
3,240
68
150
61
Electric 208V
PHV1000ER
1150(l) x 436(d) x 296(h)
45(l) x 17(d) x 12(h)
1104 x 436
208V~3P&N
1@1/4
6/12
20,490/40,980
12.6
11.0
2,170
2,750
1,620
42
93
59
PHV1500ER
1650(l) x 436(d) x 296(h)
65(l) x 17(d) x 12(h)
1604 x 436
208V~3P&N
1@1/3
9/18
30,735/61,470
18.7
11.0
2,170
3,840
2,260
57
126
60
PHV2000ER
2240(l) x 436(d) x 296(h)
88(l) x 17(d) x 12(h)
2109 x 436
208V~3P&N
2@1/4
12/24
40,980/81,970
25.1
11.0
2,170
5,500
3,240
76
168
61
LPHW 120V
PHV1000WR
1150(l) x 436(d) x 296(h)
45(l) x 17(d) x 12(h)
1104 x 436
120V~1P&N
1@1/4
12
40,490
3.2
10.5
2,060
2,500
1,470
45
99
59
PHV1500WR
1650(l) x 436(d) x 296(h)
65(l) x 17(d) x 12(h)
1604 x 436
120V~1P&N
1@1/3
18
61,470
5.0
10.5
2,060
3,500
2,060
59
130
60
PHV2000WR
2240(l) x 436(d) x 296(h)
88(l) x 17(d) x 12(h)
2190 x 436
120V~1P&N
2@1/4
24
81,970
6.5
10.5
2,060
5010
2,950
78
172
61
Electric 600V
PHV1000ER
1150(l) x 436(d) x 296(h)
45(l) x 17(d) x 12(h)
1104 x 436
600V~3P&N
1@1/4
6/12
20,490/40,980
12.7
11.0
2,170
2,750
1,620
42
93
59
PHV1500ER
1650(l) x 436(d) x 296(h)
65(l) x 17(d) x 12(h)
1604 x 436
600V~3P&N
1@1/3
9/18
30,735/61,470
19.5
11.0
2,170
3,840
2,260
57
126
60
PHV2000ER
2240(l) x 436(d) x 296(h)
88(l) x 17(d) x 12(h)
2190 x 436
600V~3P&N
2@1/4
12/24
40,980/81,970
25.4
11.0
2,170
5,500
3,240
76
168
61

Electric units require a “4 wire + ground” electric supply cable to allow for the hook up of N (neutral).
Noise levels are given as a guide only. Variations from this can arise depending on the size of the room the unit is installed in, its acoustic characteristics and the position of the listener.


Back To Home